Looking for those hard to find PC Boards? We have them cheaper than you can find elsewhere. If you see it cheaper, PLEASE give us a chance to beat that price for you. We have the widest variety of boards in the industry. If you don't see it, just ask. We have boards from .005" thick to double sided boards with 4 oz. of copper on each side.

Buy Your Photo Resist HERE !!

ONLY available at INJECTORALL

 

Material Safety Data Sheet for Sodium Persulfate
(PC200)

 

I. PRODUCT INFORMATION

TRADE NAMES / SYNONYMS Sodium Persulfate, SPS ( PC 200 Etchant )
CHEMICAL NAME Sodium Peroxodisulfate
CAS NUMBER 7775-27-1
CHEMICAL FAMILY Inorganic Peroxycompounds
CHEMICAL FORMULA Na2S2O8
MANUFACTURER
Degussa Corporation
65 Challenger Road
Ridgefield Park, NJ 07660
201-641-6100
EMERGENCY TELEPHONE 205-443-1634
REVISED 3/4/92
SUPERSEDES 7/6/90

This material is in compliance with the Toxic Substances Control Act

 

II. SUMMARY OF HAZARDS

CAUTION: This product is a strong oxidizer which may release oxygen and promote the combustion of flammable material. Sensitization may occur from the inhalation and skin contact of this product. Direct contact may cause irritation of the eyes, skin, and respiratory tract.

See Section V for additional information on health hazards.

 

III. HAZARDOUS COMPONENTS

NOTE: OSHA establishes a PEL of 15 mg/m3 ( total dust ) and 5 mg/m3 ( respirable dust ) for "Particulates Not Otherwise Regulated." The ACGIH TLV is 10 mg/m3 for these particles. Risks include reduced visibility and physical irritation.

EXPOSURE LIMITS

NAME
CAS NO.
%
PEL
TLV
OTHER
Sodium Peroxidisulfate
7775-27-1
100%
None
10 mg/m3
5 mg/m3

No carcinogenicity designated by NTP, IARC, OSHA, or others.

 

IV. CHEMICAL AND PHYSICAL PROPERTIES

The pH level corresponds to 560 grams in 1 liter H2O @ 68 F.

BOILING POINT: Not applicable
VAPOR PRESSURE: Not applicable
MELTING POINT: Decomposes @ 356 F
VAPOR DENSITY: Not applicable
SOL. IN WATER: 550 g/l
SPECIFIC GRAVITY: 2.59 ( H2O = 1 )
pH: 2.6
EVAPORATION RATE: Not applicable
APPEARANCE/ODOR: White crystals with no odor

 

V. HEALTH HAZARD DATA & FIRST AID PROCEDURES

 

TOXICITY DATA

CHEMICAL NAME LD50 LC50
Sodium Peroxidisulfate 1000 mg/kg oral, rat Not established

 

EYE CONTACT: May cause eye irritation. In case of contact, flush eyes with water. Call a physician if irritation persists.
SKIN CONTACT: May cause irritation. In case of contact, wash skin with soap and water. Call a physician if irritation persists.
SKIN ABSORPTION: Not expected to be absorbed through skin. In case of contact, flush skin with soap and water.
INHALATION: May cause irritation to the respiratory tract. If inhaled and irritation occurs, remove to fresh air. If irritation persists, call a physician.
INGESTION: Expected to cause irritation to the gastrointestinal tract. If swallowed, give victim a glass of water and induce vomiting at the instruction of a physician. Never give anything by mouth to an unconscious person.
CHRONIC EFFECTS OF OVEREXPOSURE: No chronic ( long term ) effects are known for humans.
OTHER HEALTH EFFECTS: Medical conditions which may be aggravated by exposure to this product include: Conjunctivitis of the eye, dermatitis of the skin, asthma, and respiratory diseases.

 

VI. EXPOSURE CONTROL MEASURES

EYE PROTECTION: Eye protection is required.
PROTECTIVE GLOVES: Wear chemical resistant gloves.
RESPIRATORY PROTECTION: Atmospheric levels should be maintained below the exposure limits listed in Section III by using engineering controls. If not feasible, use an approved air-purifying respirator with approved filters and/or sorbents.
OTHER PROTECTION: If repeated or prolonged skin contact or contamination is likely, protective clothing should be worn.
VENTILATION: Provide general and/or local exhaust ventilation in enclosed areas to maintain airborne concentrations at a minimum. Refer to " Industrial Ventilation" by ACGIH for a manual of recommended practices.
PERSONAL HYGIENE / WORK PRACTICES: Establish good personal hygiene and work practices. Always wash hands and face before eating, drinking, or smoking.

 

VII. FIRE AND EXPLOSION HAZARD DATA

FLASH POINT
(METHOD USED )
Non-combustible
FLAMMABLE LIMITS - LOWER: None
FLAMMABLE LIMITS - UPPER: None
EXTINGUISHING MEDIA: Use water, CO2, or dry powder.
FIRE FIGHTING INSTRUCTIONS: Evacuate enclosed and surrounding areas. If smoke and fumes cannot be avoided. use proximity suit and self-contained breathing apparatus.
UNUSUAL FIRE AND EXPLOSION HAZARDS: Product may release oxygen, promoting ignition of combustible materials.
STABILITY: This product is stable.
INCOMPATIBILITY: Combustible substances, strong bases, and alkalis.
HAZARDOUS PRODUCTS OF DECOMPOSITION: Can include oxygen and oxides of sulfur.
HAZARDOUS POLYMERIZATION: Will not undergo hazardous polymerization.

 

VIII. ENVIRONMENTAL & DISPOSAL INFORMATION

 

GENERAL

CERCLA/SARA requires notification to the appropriate Federal, State, and local authorities of releases of hazardous or extremely hazardous quantities equal to or greater than the Reportable Quantities ( RQs) in 40 CFR 302.4 and 40 CFR 355. This product contains no Reportable Quantities.

SARA Title 313 requires submissions of annual reports of releases of toxic chemicals that appear in 40 CFR 372. Components present in this product at a level which could require reporting under the statute are: NONE.

ACTION TO TAKE

FOR SPILLS / LEAKS: See Section V and VI for hazards and exposure controls. sweep up, place in drum lined with acid resistant material and rinse area with water. Do not allow contact with combustible material. Keep material dry. In case of emergency, contact Degussa at (205) 653-0632 for assistance.

DISPOSAL METHOD: This material is an oxidizer defined by DOT, therefore a hazardous waste ( per RCRA ) due to Ignitability. Disposal should be conducted by an EPA permitted disposal facility. Contact Degussa at (205) 443- 4000 ext. 2287 for assistance.

 

IX. PRECAUTIONS FOR SAFE HANDLING, STORAGE, AND USE

Store tightly closed in a cool, dry area separated from flammable materials. Avoid contamination; avoid exposure to heat and moisture.

 

X. SHIPPING INFORMATION

PRIMARY HAZARD: Oxidizer
SECONDARY HAZARD: None
DOT SHIPPING NAME: Sodium Persulfate
HAZARD CLASS: Oxidizer
UN #: 1505
UN CLASS: 5.1
PACKING GROUP #: III
49 CFR REFERENCE: 173.213, 173.240 ( HM-181 )
LABEL(S): Oxidizer
PLACARD(S): Oxidizer
SHIPPING RESTRICTIONS:
Passenger Aircraft
25 kg maximum per package
SHIPPING RESTRICTIONS:
Cargo only Aircraft:
100 kg maximum per package
AUTHORIZED CONTAINER TYPE(S): See 49 CFR section referenced above.

 

XI. ADDITIONAL INFORMATION

Product is a RCRA characteristic hazardous waste. RQ = 100#
For additional non-emergency MSDS information, contact or write your local Degussa Sales / Marketing Representative or:
Applied Technology Group Corporate Safety Department
4 Pearl Court Degussa Corporation
Allendale, NJ 07401 PO Box 606
Theodore, AL 36590
( 201 ) 818-3700
( 205 ) 443-4000

 

NOTICE

The data contained herein is based on information that Degussa believes to be reliable, but no expressed or implied warranty is made with regard to the accuracy of such data or its suitability for a given situation. Such data relates only to the specific product described and not to such product in combination with any other product and no agent of Degussa is authorized to vary any of such data. Degussa Corporation and its agents disclaim all liability for any actions taken or forgone on reliance upon such data.

 

[ Home | Products & Services | Instruction Sheets | MSDS Sheets ]

[ Online Price Sheet | Tech Sheets ]

[ Order Form | Frequently Asked Questions ]

Contact Information

Telephone

516-349-1273

FAX

631-563-3389

Postal address

40 Diamond Drive, Plainview NY 11803

 

 

Electronic mail

General Information: injectorall@mindspring.com

Copyright 2003 Injectorall Electronics Corp.

Last Modified: June 22, 2001